Data Sheets |
|
|
|
Standard |
Description |
Data Sheet |
|
IEC 61000-4-2 |
Electrostatic discharge immunity test |
|
|
IEC 61000-4-4 |
Surge/Burst immunity test, � 5 kV |
|
|
Surge/Burst immunity test � 5
kV |
||
|
IEC 61000-4-4 |
Electrical fast transient immunity test 5kV |
|
|
IEC 61000-4-5 |
Surge immunity test, � 5 kV, 2.5 kA |
|
|
� 7.0 kV, 3.5 kA |
||
|
� 10 kV, 5.0 kA |
||
|
� 12 kV, 6.0 kA |
||
|
� 24 kV, 12 kA |
||
|
IEC 61000-4-8 |
Power frequency magnetic field immunity test |
|
|
IEC 61000-4-9 |
Pulse magnetic field immunity test |
|
|
IEC 61000-4-10 |
Damped oscillatory magnetic field immunity test |
|
|
IEC 61000-4-11 |
Voltage dips, short interruptions and voltage variations immunity test |
|
|
|
||
|
IEC 61000-4-12 |
Ring-wave immunity test |
|
|
IEC 61000-4-18 |
Damped oscillatory wave immunity
test |
|
|
IEC 61730-1/2 |
HV-Impulse Generate for solar
modules |
|
|
IEC 61730-1/2 |
HV-Impulse Generate for solar
modules |
|
|
Accessories: |
||
|
IEC 61000-4-4 |
Capacitive Coupling Clamp |
|
|
Coupling-/Decoupling Networks for Surge/Burst |
|
|
|
power supply lines, up to 5kV, 3*400V / 16A |
||
|
power supply lines, up to 5kV, 3*400V / 32A |
||
|
power supply lines, up to 5kV, 3*400V / 63A |
||
|
power supply lines, up to 7kV, 3*400V / 16A |
||
|
power supply lines, up to 7kV, 3*400V / 32A |
||
|
power supply lines, up to 7kV, 3*400V / 63A |
||
|
power supply lines, up to 10 kV, 3*400V / 16A |
||
|
power supply lines, up to 10 kV, 3*400V / 32A |
||
|
power supply lines, up to 10 kV, 3*400V / 63A |
||
|
power supply lines, up to 12 kV, 2*240V / 16A |
||
|
signal lines, up to 2.5 kV, 4*240V / 10A |
||
|
signal lines, up to 2.5 kV, 4*60V / 2A |
||
|
signal lines, up to 2.0 kV, 8*60V / 2A |
||
|
IEC 61000-4-4 |
Burst Calibration Kit |
|
|
IEC 61000-4-5 |
Surge Calibration Kit |
|
|
IEC 61730-1/2 |
Capacitor Calibration Kit |
|
|
Standard |
Description |
Data Sheet |
|
FCC Part 68 |
Telecom surge immunity test: |
|
|
1.2/50�s � 6 / 10 kV |
||
|
10/700�s, �5 kV |
||
|
1.2/50�s, 10/700�s, �5 kV |
||
|
1.2/50�s, 10/700�s, �6.3 kV |
||
|
1.2/50�s, 10/700�s, � 10 kV |
||
|
1.2/50�s, 10/700�s, � 12 kV |
||
|
0.5/700�s,10/700�s, �14 kV |
||
|
10/700�s, � 20 kV |
||
|
|
Telecom surge immunity test: |
|
|
FCC Part 68 |
2/10�s, � 5 kV up to 4*100/500 A |
|
|
|
Telecom surge immunity test: |
|
|
FCC Part 68 |
10/160 �s, � 3.6 kV, 480 A |
|
|
|
Impulse life test / hold over test: |
|
|
ITU-T K44 |
10/700�s,10/1000�s,2*100A |
|
|
ITU-T K44 |
impulse spark-over test:
100-5000 V/�s |
|
|
ITU-T K44 |
Power induction test |
|
|
Description: |
Data Sheet |
|
ELECTRO STATIC DISCHARGE
GENERATOR |
|
|
LECTRO STATIC DISCHARGE
GENERATOR |
|
|
ELECTRO STATIC DISCHARGE
GENERATOR |
|
|
ELECTRICAL FAST
TRANSIENT GENERATOR |
|
|
Compact EMC test unit,
|
|
|
RING-WAVE GENERATOR |
|
|
OSCILLATORY WAVE
GENERATOR |
|
|
POWER FAIL SIMULATOR |
|
Description |
Data Sheet |
|
Accessories for CE-TESTER |
|
|
Variable Power
Source |
|
|
Helmholtz Coil |
|
|
Capacitive
Coupling Clamp |
|
|
Surge
Calibration Kit |
|
|
Burst
Calibration Kit |
|
|
Coupling-/Decoupling for CE-TESTER |
|
|
pulses to power supply
lines 3 * 400 V, 16 A, 32
A or 63 A, |
|
|
pulses to data lines, 4
* 48 V, 2 A, max. test
voltage: |
|
|
pulses to data lines, 4 * 240 V, 10 A, max. test voltage: 2 kV, 1.2/50�s |
|
|
pulses to data lines, 8 * 48 V, 10 A, max. test voltage: 2 kV, 1.2/50�s |
|
|
Data Sheet |
Description |
|
CWG Series: |
COMBINATION WAVE
GENERATORS |
|
COMBINATION WAVE
GENERATOR, IPG 105 |
|
|
COMBINATION WAVE
GENERATOR, PG2.5-32 |
|
|
COMBINATION WAVE
GENERATOR, CE-SURGE |
|
|
COMBINATION WAVE
GENERATOR, PG 6-204 |
|
|
COMBINATION WAVE
GENERATOR, PG 10-504 |
|
|
COMBINATION WAVE
GENERATOR, PG 12-804 |
|
|
COMBINATION WAVE
GENERATOR, PG 24-2500 |
|
Data Sheet |
Description |
|
Accessories for CE-SURGE
|
|
|
Helmholtz Coil |
|
|
Surge Calibration
Kit |
|
|
Coupling-/Decoupling Network for CE-SURGE |
|
|
three-phase power supply
lines 3 * 400 V, 16 A, 32 A or
63 A |
|
|
for data lines, 4 * 48 V, 2 A, max. test voltage: 2.5 kV, 1.2/50�s |
|
|
for data lines, 4 * 240 V, 10 A, max. test voltage: 2.5 kV, 1.2/50�s |
|
|
for data lines, 8 * 48 V, 10 A, max. test voltage: 5 kV, 1.2/50�s |
|
|
Copyright � 2001-2023 R. A. Mayes Company, Inc. An Electro Mechanical Research and Development (EMRAD) Corporation, Company See our Privacy Policy All the data files on our website require Adobe Acrobat Reader! |