OPHIR RF designs and manufactures High Power, Solid State,
Broadband RF and
Band-specific amplifiers. Our products range in frequency from 10 kHz to 8 GHz, with power levels from 1 Watt to above 2000 Watts. Broadband markets served by OPHIR RF include immunity and emissions testing, Military, SATCOM, TACSAT, EMC/EMI/RFI, medical imaging MRI/NMR, TWT replacement, general laboratory equipment and much more.
|
 |
|
 |
2 Year Parts & Labor Warranty
On All
Amplifier Systems & Amplifier Modules |
 |
 |
|
Solid State Microwave Amplifiers
Broadband & Narrowband
Sorted by Frequency Range -
Click Model Number for Data file (.pdf) |
Amplifier
Model
Number |
Frequency
Range |
CW
Output
(Saturated) |
Linear
Output
( P1dB) |
Gain
dB |
Flatness
±dB |
IP3
dBm |
5141 |
0.7 - 3.0 GHz |
15 Watts |
12 Watts |
43 dB |
±2.0 |
+51 |
5142 |
0.7 - 3.0 GHz |
30 Watts |
24 Watts |
46 dB |
±2.0 |
+54 |
5143 |
0.7 - 3.0 GHz |
50 Watts |
40 Watts |
48 dB |
±2.0 |
+56 | |
4015
|
0.8 - 1.0 GHz |
50 Watts |
30 Watts |
48 dB |
±1.5 |
+51 | |
4014
|
0.8 - 1.0 GHz |
100 Watts |
60 Watts |
51 dB |
±1.5 |
+54 | |
4009
|
0.8 - 1.0 GHz |
200 Watts |
100 Watts |
54 dB |
±1.5 |
+58 | |
4010
|
0.8 - 1.0 GHz |
300 Watts |
150 Watts |
56 dB |
±1.5 |
+61 |
5002A |
0.8 - 2.0 GHz |
7 Watts |
5 Watts |
39 dB |
±1.5 |
+47 |
5028A |
0.8 - 2.0 GHz |
12 Watts |
10 Watts |
41 dB |
±1.0 |
+51 |
5016A |
0.8 - 2.0 GHz |
25 Watts |
20 Watts |
44 dB |
±1.5 |
+53 |
5022A |
0.8 - 2.0 GHz |
50 Watts |
40 Watts |
48 dB |
±1.5 |
+57 |
5038A |
0.8 - 2.0 GHz |
100 Watts |
80 Watts |
51 dB |
±2.0 |
+59 |
5063A |
0.8 - 2.0 GHz |
200 Watts |
150 Watts |
54 dB |
±2.0 |
+62 |
Model |
Frequency |
CW |
P1dB |
Gain |
Flatness |
IP3 |
5150 |
0.8 - 2.5 GHz |
13 Watts |
10 Watts |
42 dB |
±2.0 |
+50 |
5151 |
0.8 - 2.5 GHz |
25 Watts |
20 Watts |
45 dB |
±2.0 |
+53 |
5152 |
0.8 - 2.5 GHz |
50 Watts |
40 Watts |
48 dB |
±2.0 |
+56 |
5153 |
0.8 - 2.5 GHz |
80 Watts |
60 Watts |
50 dB |
±2.0 |
+58 |
5154 |
0.8 - 2.5 GHz |
150 Watts |
120 Watts |
52 dB |
±2.0 |
+61 |
5155 |
0.8 - 2.5 GHz |
250 Watts |
200 Watts |
55 dB |
±2.0 |
+63 |
5156 |
0.8 - 2.5 GHz |
500 Watts |
400 Watts |
58 dB |
±2.0 |
+66 |
5056 |
0.8 - 4.2 GHz |
1.2 Watts |
1 Watt |
30 dB |
±1.5 |
+41 |
5161 |
0.8 - 4.2 GHz |
15 Watts |
12 Watts |
43 dB |
±2.0 |
+51 |
5162 |
0.8 - 4.2 GHz |
28 Watts |
22 Watts |
46 dB |
±2.0 |
+54 |
5163 |
0.8 - 4.2 GHz |
50 Watts |
40 Watts |
48 dB |
±2.0 |
+56 |
5164 |
0.8 - 4.2 GHz |
100 Watts |
70 Watts |
51 dB |
±2.0 |
+58 |
5165 |
0.8 - 4.2 GHz |
200 Watts |
135 Watts |
54 dB |
±2.0 |
+61 |
5166 |
0.8 - 4.2 GHz |
500 Watts |
200 Watts |
58 dB |
±1.0 |
+63 |
Model |
Frequency |
CW |
P1dB |
Gain |
Flatness |
IP3 |
|
4008 |
950 -
1350 MHz |
15
Watts |
12 Watts |
42 dB |
±1.0 |
+50 |
|
4045 |
950 -
1450 MHz |
60
Watts |
40 Watts |
49 dB |
±1.0 |
+56 |
|
4040 |
950 -
1215 MHz |
200
Watts |
150 Watts |
54 dB |
±.75 |
+62 |
5046 |
1.0 - 2.0 GHz |
1.2 Watts |
1 Watts |
30 dB |
±1.5 |
+40 |
5135 |
1.0 - 2.0 GHz |
300 Watts |
250 Watts |
56 dB |
±2.0 |
+64 |
5171 |
1.0 - 3.0 GHz |
15 Watts |
12 Watts |
43 dB |
±1.5 |
+51 |
5172 |
1.0 - 3.0 GHz |
30 Watts |
24 Watts |
46 dB |
±1.5 |
+54 |
5173 |
1.0 - 3.0 GHz |
50 Watts |
40 Watts |
48 dB |
±2.0 |
+56 |
5174 |
1.0 - 3.0 GHz |
100 Watts |
80 Watts |
51 dB |
±2.0 |
+59 |
5175 |
1.0 - 3.0 GHz |
200 Watts |
150 Watts |
54 dB |
±2.0 |
+62 |
4056
 |
1175 - 1675 MHz |
500 Watts | |
58 dB |
±1.5 |
+63 |
5097 |
1.35 - 1.85 GHz |
200 Watts |
160 Watts |
54 dB |
±1.5 |
+62 |
Model |
Frequency |
CW |
P1dB |
Gain |
Flatness |
IP3 |
|
4003
|
1.8 - 2.0 GHz |
120 Watts |
100 Watts |
52 dB |
±.75 |
+60 |
|
4064 |
1.8 -
2.5 GHz |
60
Watts |
50 Watts |
49 dB |
±1.0 |
+57 |
|
4062
|
1.85 - 2.17
GHz |
60 Watts |
45 Watts |
50 dB |
±.75 |
+59 |
|
4060
|
1.85 - 2.17
GHz |
120 Watts |
100 Watts |
53 dB |
±.75 |
+61 |
|
4061
|
1.85 - 2.17 GHz |
200 Watts |
160 Watts |
53 dB |
±1.0 |
+62 |
5181 |
2.0 - 4.0 GHz |
15 Watts |
12 Watts |
43 dB |
±1.5 |
+51 |
5182 |
2.0 - 4.0 GHz |
30 Watts |
24 Watts |
46 dB |
±1.5 |
+54 |
5183 |
2.0 - 4.0 GHz |
50 Watts |
40 Watts |
48 dB |
±2.0 |
+56 |
5184 |
2.0 - 4.0 GHz |
100 Watts |
80 Watts |
51 dB |
±2.0 |
+59 |
5185 |
2.0 - 4.0 GHz |
200 Watts |
150 Watts |
54 dB |
±2.0 |
+62 |
5190
 |
2.0 -
6.0 GHz |
9 Watts |
6 Watts |
40 dB |
±1.0 |
+46 |
5191
 |
2.0 -
6.0 GHz |
15 Watts |
10 Watts |
43 dB |
±1.0 |
+50 |
5192
 |
2.0 -
6.0 GHz |
25 Watts |
15 Watts |
45 dB |
±1.0 |
+52 |
5193
 |
2.0 -
6.0 GHz |
50 Watts |
30 Watts |
50 dB |
±1.0 |
+54 |
|
4021
|
2.2 - 2.4 GHz |
12 Watts |
10 Watts |
40 dB |
±1.0 |
+50 |
|
4057 |
2.4 -
2.5 GHz |
10
Watts |
8 Watts |
41 dB |
±.75 |
+49 |
|
4058 |
2.4 -
2.5 GHz |
50
Watts |
40 Watts |
48 dB |
±.75 |
+56 |
|
4022 |
2.7 -
3.2 GHz |
200
Watts |
150 Watts |
54 dB |
±1.5 |
+62 |
|
4073
|
5.9 - 6.4
GHz |
12 Watts |
10 Watts |
45 dB |
±1.0 |
+50 |
|
4074
|
5.9 - 6.4 GHz |
30 Watts |
25 Watts |
48 dB |
±1.5 |
+54 |
|
Amplifier Options |
|
Option |
Description |
Specific | |
Option E |
Front panel digital display, forward and reverse power readings, gain adjustment, ALC on/off, fault indication, standby mode, and rear panel IEEE-488 HPIB, inclusive |
Installed at Time of Order or Retrofit | |
Option F |
Front Panel Connectors |
Standard | |
Option R |
Rear Panel Connectors |
No Charge if Installed at Time of Order | |
Option S |
Rack Mounting Slides | | |
Option T |
Ethernet Interface, Requires Option E above |
Installed at Time of Order or Retrofit |
All the Data Sheets on our site require
Adobe Acrobat Reader!

|